Titan Outdoor Cabinet Energy Storage System

Contact Us

Looking for more details? We’re ready to assist!

Contact Us

◆ MQK-25~50 suits large residential or small industrial and commercial scenarios.

◆ Supports 150% photovoltaic over-allocation, reducing grid demand and strengthening the independence of green energy.

◆ Adopts safe 200Ah lithium iron phosphate (LFP) battery, supporting 0.5C charge and discharge.

◆ Supports self-consumption, time-of-use electricity pricing, and backup power for diverse daily scenarios.

◆ Controls external loads like heat pumps, optimizing energy consumption.

◆ Suitable for scenarios with an unstable or absent power grid, such as micro power grids and isolated islands.

MQK-30k~50k 

Inverter Parameters

Model MQK-25 MQK-30 MQK-40 MQK-50
DC Input
Max.PV Aeray Power [Wp]@SIC 37500 45000 60000 75000
Max.DC Voltage [V] 1000
MPPT Voltage Range [V] 200 850
Rated DC Voltage[V] 620
Start Voltage[V] 135
Max.DC Input Current [A] 4*30 4*30 4*30 4*30
Max.DC Short Circuit Current [A] 4*40 4*40 4*40 4*40
Number of MPPT 4 4 4 4
Number of Strings per MPPT 2 2 2 2
Battery Parameters
Battery Typo LiFeP04
Battery Voltage Range [V] 135 750
Max.Charging/Diecharging Current [A] 100-100
AC Parameters [On gid]
Rated AC Power [W] 25000 30000 40000 50000
Maximum output apparent power [VA] 27500 33000 44000 55000
Maximum input apparent power [VA] 30000 36000 48000 60000
Maximum battery charging power [W] 25000 30000 40000 50000
Rated Voltage [V] 3L/N/PE:220/380V:230/400V;240/415V
On-grid Frequency Dt] 50/60
Maximum current output [A] 42 50 66 83
Powor Factor 0.Bloading 0.8lagging
Total Harmonic Distortion[THD]
AC Parameters [Back up]
Rated AC Power [W] 25000 30000 40000 50000
Maximum output apparent power [VA] 27500 33000 44000 55000
Maximum current output [A] 42 50 66 83
UPS switching time
Rated output voltage [V] 3L/N/PE:220/380V;230/400V,240/415V
Rated Ac FrequencyDtr] 50/60
Output THDv@Liner Load)
AC Parameters[Generator]
Maximum input apparent power[VA] 30000 36000 48000 60000
Maximum battery charging power[W] 25000 30000 40000 50000
Rated output voltage[V] 3L/N/PE:220/380V,230/400V;240/415V
Rated Ae Frequency Dtz] 50/60
Efficiency
Maximum PV conversion efficioncy 98.8%
Euro Efficiency 98.3%
Protection Protecion
Battery input reversoconnection protection Integrated
Insulation rotintance protection Integrated
Surge protection Integrated
Over-temperature protection Integrated
Anti-islanding Protection Integrated
Residual current protection Integrated
AC aver-voltage protection Integrated
Overload protection Integrated
AC short-circuit protection Integrated

Model MQK-25 MQK-30 MQK-40 MQK-50
General Parameters
Over voltage category PV.II:Main:II
Dimensions(mm) 800x620x300
Weight (KG) 72.0
Protection degreo IP65
Standby sell-consumption(W)
Topology Transformerloss
Operating Temperature Range("℃) -30-60
Relative Humidity(%) 0-100
Operating Altitude (m) 3000(>3000m derating)
Cooling Smart fan
Noise Level(dB)
Display OLED & LED
Communcation CAN,RS485,WFi/LAN(Optional)

Model CB2-62.9-HV5 CB2-83.9-HV5 CB2-104.9-HV5
Rated Energy [kWh] 62.9 83.9 104.9
Usable Energy [kWh] 56.6 75.5 94.4
Rated Capacity [Ah] 205 205 205
No.of Modules 6 8 10
Nominal Voltage[V] 307.2 409.6 512
Voltage Range [V] 240~350.4 320~467.2 400~584
Charge/Discharge Current [A] 100 100 100
Rated Power [kW] 30 40 50
Weight[kg] 1030 1170 1310
Dimension[mm] 960*1500*2000 (1185*1500*2000-include air condition)
Communication CAN
Operating Temperature Range[C] -30~50
Cooling Method Air Conditioner
Relative Humidity 5~95%(non-condensing)
Altitude [m] 2000
Ingress Protection IP54
Mounting Ground-Mounted
Control Module CBC2-HV5
Weight[kg] 30
Dimension[mm] 870*603*204
Battery Module CBU2-10.496-HV5
Rated Energy[kWh] 10.496
Battery Module Serial Cell Quantity (pcs) 16
Weight[kg] 71
Dimension[mm] 607*400*246
Applicable Standard IEC62619-2017,UN38.3,IEC61000-6-2/4,IEC62477

Model MQK-E3-6k-1p MQK-E3-8k-1p
Rated Power 6000VA/6000W 8000VA/8000W
PVINPUT
Max power(kW) 7 10
Max.DC voltage(V) 500
MPPTvoltagerange(V) 90-450
Max.inputcurrent(A) 30 30
MPPT number/Max input strings number 1/2 2/2
ACOUTPUT(GRID-TIED)
Grid voltage/range(V) 230/90-280(For Personal Computers):170~280(For Home Appliances)
Frequency(Hz) 50/60
PF 0.8lagqing-0.8leading
THDI
AC outputtopology L+N+PE
BATTERY +
Battery voltage ran ge(V) 40-63
Max.charging voltage(V) 63
Max.charge/discharge current(A)100/120 100/120
Battery type Lithium/Lead-acid
UPSOUTPUT
Rated power(kW) 6 8
Rated outputvoltage(V) 220/23 0/240
Rated output current(A) 27.2/27/25 36.3/34,7/33.3
Rated frequency(Hz) 50/60
Transfer Time(ms)
THDu
Overload capacity 5110%load10sz101%~110%load
PROTECTION&FEATURE
Anfiisland protection Yes
Insulation monitoring Yes
Residual currentmonitoring Yes
Arc fault protection Yes(Optional)
Parallel function Yes,Sunits
Other protection AC overument AC oraOvertemperature protection
GENERAL PARAMETER
Efficiency(Peak) 93%
Degree of protection IPS5
Operation temperature -25*C~50℃>45°Cderating
Cooling smartcooling
Relative humidity 5~95%(non-condensing)
Altitude (>2000m Derating)
DimensionsWx DxH(mm) 345*197*630
Net Weight(Kg) 22.5 32
Isolation transformer No
Self-consumption(W)
DISPLAYAND COMMUNICATION
Display Touch screen
Interface Standard:RS232,CAN&RS485,Optional:WiFi,CT
Safety standard ENIECS2109-1,ENIEOS2109-2

Leave us a Message